IWSF Homologation Dossier InputInternational Water Ski Federation 2001 Edition Homologation Dossier IMPORTANT NOTICE: It is not the intent of this form to add hours of extra work to the homologator's job, but rather to provide a quick checklist that gives visibility of the technical effort to the general skiing public. START OF HOMOLOGATION FORM Please fill in the blanks below: Number code of competition: 04M106L Important Note: The globally unique tournament code must be input here or the report will not be processed. This code is the tournament code in one of two formats. The US format of 00E035R or the non-US format of 00FRA27 must be entered here. Name of competition: GARRY LICHLITER OPEN-CORRECTED Date:07/11/04 Venue:DUQOIN, ILL. Country:USA Were cash prizes or merchandise awarded? NO Homologator's and Chief Judge recommendation to Tournament Council (Fill in R-Record, L-Standing List, N-Not list capable) EventRound 1Round 2Round Slalom ( L )( L ) Figures ( L )(L) Jump ( L )( L ) OBLIGATORY COMPOSITION OF DOSSIER: 1 copy of this document including the homologation notice HOMOLOGATOR'S CHECKLIST If checked and all according to rules put OK in brackets. If checked and any variation to the rules put an X in the brackets and explain in "Remarks" section on last page. Not applicable is NA. 1. Boats and equipment (W 10.01) ( OK) 2. Speed Control (W 10.07) ( OK ) Maunfacturer: PERFECT PASS Software Version: 6.5XY used in slalom ( OK) used in figures ( OK) used in jump ( OK) 3. Arrangement for checking skis (W 10.03) ( OK ) 4. Measure lines and handles (W 10.04) ( OK ) slalom ( OK ) jump ( OK ) handles ( OK ) 5. Arrangement for checking of skier supplied handles (W 10.06) ( OK ) 6. Timing devices (W 11.03) ( OK ) 7. Homologation notice posted before start( OK ) 8. Automatic timing-jump ( OK) 9. Jump distance indication (W 13.11) ( OK ) 10.Video Jump Distance measurement (W 13.11)( OK ) Backup ( Video TapeS 11.Automatic timing-slalom ( OK ) 12.Position and height of slalom towers ( OK ) (W 14.05 and W diagram 6) 13.Slalom buoys (W 14.06) ( OK ) 14.VHS video slalom endcourse (W 14.17) ( OK ) 15.Trick course checked (W diagram 3) ( OK ) 16.Position and height of trick towers ( NA ) (W 15.11) 17.Semi-automatic timing-20sec (W 15.12) ( OK ) with automatic median start ( OK ) 18.VHS video tricks (W15.15) ( OK) 19.7,000/10,000 points review judge (W 15.15) ( OK ) SLALOM COURSE Cross-Line coursE JUMP COURSE JUMP MEASUREMENT SETUP VIDEO JUMP 40m test buoy (40-50m) XY-OK survey -DONE video system CORSON VJ 60m test buoy (60-70m) XY-OK survey -DONE video system - CORSON VJ JUMP RAMP Width at top (W 13.02a) 4.29m Width at bottom 4.28m Top edge to 6.4m line left side (W 13.02b,h) 6.4m Top edge to 6.4m line right side (W 13.02b.h) 6.4m Top edge to 6.7m line left side (W 13.02b,h)6.71 m Top edge to 6.7m line right side (W 13.02b.h) 6.72m Length underwater from 6.7m line (W 13.02c).75 m Maximum Deviation from plane Diagonal string measurement (W 13.02f) 1.1cm Center string measurement (W 13.02f) 1.2cm Apron under water (W 13.02g) ( OK ) Apron full length (W 13.02g) ( OK ) Sighting line (W 13.02i) ( OK ) Secure anchoring (W 13.02i) ( OK ) Apron Angle (W 13.02k) Jump Heightm (a) length of edge of apron from top corner to waterm (b) ratio of b/a (automatic calculation) ratio in tolerance minimum 0.883 maximum 0.643( OKX ) RAMP SETTING (ratio calculated automatically) Right SideLeft Side SettingHeightLengthRatioHeightLengthRatio 1.50-160cm-680cm-0.2353cm 160cm680cm0.2353cm 1.65-174cm-680cm-0.2559cm 174cm680cm0.2559cm 1.80cmcmcm cmcmcm NON-VIDEO JUMP Note: The following section is only to be completed if the jumps were measured by protractors rather than video. Automatic meter system used ( NOYES) Protractor reading units ( DegreesGrads) METER SETUP Distance (T1 - T2/A - B) ()m Distance (T2 - T3/B - C) ()m Distance (T1 - T3/A - C) ()m *if AC not a straight line Inter-meter angles (if not a straight line) T1/A T2/BT3/C Meter T1/AXXXXXXX Meter T2/BXXXXXXX Meter T3/CXXXXXXX SET UP SIGHTINGS AngleRamp15ET T1/A upper T1/A lower T2/B upper T2/B lower T3/C upper T3/C lower Using average of upper and lower readings (max difference 0.1 degrees) list the error triangles with an inscribed circle diameter (max 0.15) inscribed circle diameter at ramp meters *inscribed circle diameter at 15ET meters Jump system survey results (X-Y coordinates) XY Ramp Table 1/A Table 2/B Table 3/C Buoy 15ET Computer program checked against Computer Benchmark for Computed Distances OKX METER STATIONS Stability and horizontal level ( OKX ) Protractors on same vertical line ( OKX ) Protractor graduations (max 0.2 degrees) ( OKX ) Radius of protractors (min 0.25 m) ( OKX ) Accuracy of sighting arms ( OKX ) END OF HOMOLOGATION FORM HOMOLOGATOR'S REMARKS Give details of any variations of IWSF rules. List any alterations to the course, etc. during the competition. List any malfunction of equipment. Give any further information which might affect the Tournament Council's assement of the homologation. Any category marked with an "X" above should be explained here. Remarks: SURVEY DONE BY DAVE CLARK 7/10/04 ALL BUOYS WITHIN TOLERANCE, USED GATE VIDEO WIRELESS CROSS LAKE WITH JUDGES ON 44 DEGREE POSITION ON OPPOSITE SIDES AND VIDEO REVIEW IN SLALOM. JUMP WAS CORSON VJ WITH XY FROM SURVEY AND CHECK BALLS WERE WITHIN TOLERANCE. USED VCR BACK UP AND 2 GRIDS WITH 2 STATIONARY CAMERAS. TRICKS WAS VIDEO FROM BOAT WITH 3 JUDGES AND WIRELESS. USED 2004 CORSON TRICK TIMER. NO RECORDS WERE SET. ALL WAS DONE TO IWSF RECORD SPECS. Homologator Name and address: CARL TRUESDALE 10845 GOLF VIEW DR. INDPLS. IN. 46234 Homologator's email address:BIGRIGBRC@AOL.COM (Put your email address in the box above to receive a confirmation of submission) Chief Judge Name and address: LARRY SMITH 3658 E. 200S ANDERSON, IN. 46017 Please submit this homologation form within 14 days of the end of the tournament. Special thanks to Ian Collins and Ross Lloyd for help with the creation, setup, and testing of this dossier input processor.